What Are the Specifications of a 3+1 CCTV Cable? B2B Guide
A 3+1 CCTV cable should be evaluated on its video conductor construction, power conductor material and size, shielding, insulation, outer jacket, and — where relevant — outdoor/UV rating and flame-retardant properties. "3+1" is a market/configuration term rather than a single fixed specification, so exact conductor sizes, materials, and construction can vary between manufacturers. Before ordering in bulk, a professional buyer should request and verify the actual datasheet rather than assuming all 3+1 cable is built the same way.
This guide is written for CCTV installers, dealers, distributors, and procurement teams evaluating 3+1 cable specifications before a bulk or repeat order — not a beginner introduction to what 3+1 cable is. If you're looking for that instead, see our 3+1 CCTV cable buying guide.
1. Cable Configuration: What Does "3+1" Actually Mean?
"3+1" refers to a cable that combines a coaxial video core with a separate power cable inside one outer jacket — one cable carrying both video signal and DC power to an analog camera. The "3" and "1" naming convention is a market term used across the industry, and it's worth being precise about what it typically includes:
- The coaxial portion — carries the video signal to the DVR
- The power portion — typically a 2-core power cable bundled alongside the coaxial core, supplying DC power to the camera
Exactly how manufacturers construct and label this can vary. Some suppliers describe the configuration differently, and conductor counts, sizes, and materials aren't standardized across the industry the same way, say, an Ethernet category spec is. Always verify the actual construction from the supplier's datasheet rather than assuming every "3+1" cable on the market is built identically.
2. Video Conductor / Coaxial Core
The coaxial portion is what carries the analog video signal, so its construction directly affects signal quality over a given run. Things a buyer should check:
- Coaxial construction — centre conductor, dielectric/insulation layer, shielding/braid, and outer jacket, in that order from the inside out
- Centre conductor material — typically copper or copper-coated steel, depending on the manufacturer; confirm which is used, since this affects signal transmission
- Conductor size — thicker conductors generally carry signal more efficiently over distance; ask for the actual diameter or AWG rating
- Shielding/braid — braid density and any additional foil shielding affect how well the cable resists interference over a run
- Dielectric/insulation — the material and consistency of the insulation layer between the centre conductor and shield
- Impedance — where specified, confirm it matches what your camera/DVR system expects (commonly referenced for coaxial video cable, though exact figures should come from the datasheet, not assumption)
- Compatibility — confirm the cable is suited to your specific analog camera system (standard analog, AHD, TVI, or CVI, where relevant), since transmission characteristics can differ
Don't assume every product labelled "coaxial" or "RG59-type" has identical internal construction — verify centre conductor material and shielding specifically, since these are the details most likely to vary between suppliers at similar price points.
3. Power Conductor Specifications
The power portion of a 3+1 cable delivers DC power to the camera, and its specification matters just as much as the video core, particularly for longer runs.
- Number of power cores — typically 2 (positive and negative), bundled alongside the coaxial core
- Core size — thicker cores carry current more efficiently with less resistance
- Conductor material — pure copper or CCA (covered in detail below)
- AWG / conductor diameter — request the specific figure rather than relying on the overall cable's outer diameter as a proxy
- Current carrying capability — should be assessed against your camera's actual power draw, not assumed to be sufficient for every camera type
- Voltage drop considerations — becomes more significant on longer runs; a thinner conductor or lower-conductivity material will show more voltage drop over the same distance
There is no single AWG or core size that's "correct" for every installation — the appropriate specification depends on your camera's power requirements and the run distance. A buyer sourcing cable for short indoor runs with low-power cameras has different requirements than one sourcing for longer outdoor runs with higher-draw cameras (like PTZ units or cameras with strong IR).
4. Pure Copper vs CCA
This is one of the most important specifications to verify in bulk procurement, since it affects both the video and power performance of the cable.
| Factor | Pure Copper (100%) | CCA (Copper Clad Aluminium) |
|---|---|---|
| Conductivity | Higher, more consistent | Lower — aluminium core with a thin copper coating |
| Resistance | Lower resistance per given conductor size | Higher resistance than pure copper of the same size |
| Voltage drop | Generally lower over a given run | Generally higher over the same run, more noticeable at longer distances |
| Durability | More resistant to breaking at bends and connector points | Aluminium core can be more prone to fatigue and breakage under repeated flexing |
| Cost | Higher raw material cost | Lower raw material cost |
It would be inaccurate to claim CCA "always fails" or that pure copper delivers "zero signal loss" — these are engineering trade-offs, not absolutes. What's accurate to say is that pure copper generally performs more consistently for power delivery and durability, particularly on longer runs or higher-power cameras, and that the price difference between the two materials is a real and verifiable one.
Procurement verification: Conductor material claims should be checked against the supplier's datasheet, and where possible, a physical sample should be tested or inspected before committing to a bulk order — visual inspection alone often isn't enough to distinguish pure copper from CCA.
5. Cable Gauge / AWG
AWG (American Wire Gauge) describes conductor thickness — a lower AWG number means a thicker conductor. This matters for both the video core (signal transmission) and the power cores (current carrying capacity and voltage drop).
Why B2B buyers shouldn't judge cable quality by outer diameter alone: A cable can appear thick due to a heavier jacket or additional filler material, without the actual copper conductors inside being any thicker. The only reliable way to confirm conductor size is to check the specified AWG or conductor diameter in the datasheet — or, where in doubt, to have a sample tested.
Example for illustration only: a thicker power conductor (lower AWG) will generally support more current with less voltage drop over the same distance than a thinner one — but the specific AWG appropriate for your installation depends on your camera's power draw and run length, and should be confirmed against your actual requirements rather than treated as a fixed industry standard.
6. Outer Jacket
The outer jacket protects the cable and determines its suitability for different installation environments.
- Material — commonly PVC, though PE or LLDPE-based jackets are also used depending on the manufacturer and intended environment
- Jacket thickness — affects mechanical protection and durability during and after installation
- Mechanical protection — resistance to abrasion, minor impacts, and handling during installation
- Flexibility — affects how easily the cable routes through conduit, along walls, or around corners
- Environmental suitability — indoor-rated jackets are not automatically suitable for outdoor exposure; confirm the intended environment matches the jacket's rating
7. UV / Weather Resistance
For any 3+1 cable destined for outdoor use, jacket rating deserves specific attention:
- UV exposure — prolonged sun exposure can degrade jackets not specifically formulated for outdoor use, leading to cracking over time
- Rain/moisture — outdoor cable needs to resist water ingress, particularly at points where the jacket may be compromised
- Temperature changes — repeated expansion and contraction can stress a jacket not designed for outdoor temperature swings
- Jacket degradation — ask specifically how the jacket is formulated for outdoor durability, rather than assuming any PVC cable is "weatherproof"
Important: Not every PVC-jacketed cable is weatherproof. Outdoor suitability should be backed by the manufacturer's stated specification or rating — if a supplier can't provide documentation on outdoor performance, treat the "outdoor" claim with caution rather than assuming it's accurate.
8. Flame Retardancy
For indoor building installations — particularly in commercial buildings, offices, or multi-unit residential properties — flame-retardant cable properties can be a relevant procurement requirement, sometimes driven by building codes or client specifications.
- Ask whether the cable jacket has flame-retardant properties, and what standard or test (if any) supports that claim
- Request actual test or rating documentation rather than accepting a verbal claim
- Consider cable routing — installations running through shared risers, ceiling voids, or fire-rated compartments are more likely to have specific requirements
Do not accept or repeat a fire certification claim without documentation. If a supplier states the cable is flame-retardant but cannot provide a test report or standard reference, that should be flagged during procurement rather than assumed to be accurate.
9. Cable Length
3+1 cable is commonly supplied in market-standard lengths such as 50m, 90m, 100m, and 180m, along with custom or bulk lengths for larger orders. That said, these aren't universal fixed standards — different manufacturers may package cable differently.
Before ordering, verify:
- Actual supplied length — confirm the roll or box genuinely contains the stated length, not an approximation
- Manufacturing tolerance — ask whether the supplier states a tolerance range for length accuracy
- Packaging — roll, box, or reel format affects handling, storage, and how the cable pays out during installation
10. Cable Diameter
Outer diameter matters for practical reasons beyond just "how thick the cable feels":
- Conduit capacity — affects how many cables can be routed through a given conduit size
- Cable management — thicker cables are harder to route through tight spaces or existing infrastructure
- Reel/box packing — affects how much cable fits on a standard reel or in standard packaging, which matters for storage and logistics
- Shipping — bulk orders with a larger outer diameter take up more space and can affect freight cost
Important: outer diameter is not proof of conductor quality. A cable can have a larger outer diameter due to heavier jacket material or filler content, without the actual copper conductors being any thicker — this is exactly why AWG/conductor diameter should be checked separately from overall cable diameter.
11. Signal and Power Performance
It's worth evaluating video and power performance as two separate considerations, since they're affected by different parts of the cable's construction.
Video Performance
- Signal transmission quality depends on centre conductor material, shielding, and dielectric consistency
- Attenuation (signal weakening over distance) increases with cable length and is affected by conductor and shielding quality
- Connector quality at both ends also affects overall signal integrity — even a well-built cable can underperform with poorly terminated connectors
Power Performance
- Conductor resistance in the power cores determines how much voltage is lost over a given run
- Voltage drop becomes more significant as distance increases or camera power draw increases
- Actual power delivered to the camera depends on the combination of conductor material, size, and run length — not a fixed number that applies to every cable
Avoid supplier claims of "zero signal loss" or similarly absolute performance promises — these aren't realistic engineering claims for any cable over a real-world distance.
12. Connector Compatibility
3+1 cable is generally associated with analog and HD-over-coax CCTV systems — not IP camera Ethernet networking. Relevant connector and system compatibility includes:
- BNC connectors — the standard connector for the coaxial video portion, connecting to the DVR
- DC power connectors — for the power portion, connecting to the camera's power input
- DVR compatibility — confirm the cable and connector setup matches your DVR's input type
- Analog/AHD/TVI/CVI systems — where applicable, confirm the cable's transmission characteristics are appropriate for the specific analog technology in use, since these can have different signal requirements
For IP cameras connecting over Ethernet, CAT5e or CAT6 is the relevant cable type instead — see our guide on types of CCTV cables and our comparison of coaxial vs CAT6 CCTV cable for that distinction.
13. Indoor vs Outdoor 3+1 Cable
| Feature | Indoor | Outdoor |
|---|---|---|
| Jacket | Standard PVC, adequate for indoor conditions | Should be specifically rated for UV and weather exposure |
| UV exposure | Not a significant factor | Major consideration — jacket must resist degradation from sunlight |
| Moisture | Minimal exposure expected | Jacket and connector sealing need to resist rain and humidity |
| Installation environment | Walls, ceilings, conduit, protected routing | Exposed runs, exterior walls, rooftop, perimeter routing |
| Protection requirements | Basic mechanical protection generally sufficient | May require additional conduit or physical protection along the route |
| Typical use | Indoor camera runs, internal building wiring | Perimeter cameras, external walls, outdoor-mounted equipment |
14. Professional Procurement Checklist
Before Ordering Bulk 3+1 CCTV Cable, Verify:
- Cable configuration (video + power arrangement)
- Video conductor material
- Power conductor material (pure copper or CCA)
- Conductor size / AWG for both video and power cores
- Shielding specification
- Insulation/dielectric material
- Outer jacket material
- Outdoor/UV rating, if required for the installation
- Flame-retardant specification, if required
- Cable length and manufacturing tolerance
- Outer diameter
- Conductor resistance figures, where available
- Voltage-drop considerations for your typical run distances
- Packaging format (roll, box, or reel)
- Batch consistency across the order
- Manufacturing details/traceability
- Sample approval before committing to bulk quantity
- Warranty/quality policy
- Supplier documentation (datasheet, test reports where relevant)
- GST/invoice requirements for B2B procurement
15. How to Read a 3+1 CCTV Cable Datasheet
Example specification format — not JUAA's specific product specification. Always request the actual datasheet from your supplier.
| Specification | What the Buyer Should Check | Why It Matters |
|---|---|---|
| Cable configuration | Exact video + power arrangement described | Confirms what the cable actually combines before ordering |
| Video conductor | Centre conductor material and size | Directly affects video signal transmission quality |
| Power conductor | Number of cores, material, and size | Determines power delivery capability to the camera |
| Conductor material | Pure copper vs CCA, clearly stated | Affects conductivity, resistance, and long-term durability |
| AWG | Specific gauge for both video and power conductors | Confirms actual conductor thickness, not just outer cable size |
| Insulation | Dielectric material used | Affects signal consistency and cable durability |
| Shielding | Braid type/density, additional foil if present | Affects resistance to interference over the run |
| Jacket | Material and thickness | Determines mechanical protection and environmental suitability |
| Outdoor rating | Explicit outdoor/weatherproof specification, if claimed | Confirms suitability for exterior installation |
| UV resistance | Stated UV resistance or test reference | Predicts long-term jacket durability under sun exposure |
| Flame retardancy | Test/standard reference, if claimed | Relevant for indoor building code or client requirements |
| Length | Stated length and tolerance | Confirms you're getting what you're paying for |
| Outer diameter | Stated diameter in mm | Relevant for conduit sizing and installation planning |
| Packaging | Roll, box, or reel format | Affects handling, storage, and installation workflow |
16. 3+1 CCTV Cable Specifications for Different Applications
A. Small Indoor CCTV Installation
Standard indoor-rated jacket is generally sufficient. Focus verification on conductor material (pure copper vs CCA) and AWG, since short indoor runs are more forgiving of jacket-related environmental concerns.
B. Residential Analog CCTV
Balance cost and quality — verify conductor material for reliability, and confirm outdoor rating specifically for any cameras mounted externally, even on an otherwise indoor-focused installation.
C. Shop Installation
Multiple cameras often mean longer aggregate cable runs — pay attention to power conductor size and voltage drop across the longest individual run in the installation.
D. Commercial Building
Flame-retardant specification and documentation become more relevant here, particularly for cable routed through shared building infrastructure or fire-rated compartments.
E. Outdoor CCTV
UV/weather rating and jacket quality deserve the most attention. Confirm outdoor rating with actual documentation rather than a verbal assurance.
F. Long Cable Runs
Conductor material and AWG matter significantly here — both for video signal attenuation and power voltage drop. This is where CCA's limitations are most likely to become noticeable. See our long-distance CCTV cable guide for more on distance-specific planning.
G. Multi-Camera Professional Installation
Batch consistency across the full order matters — verify that multiple boxes/reels from the same order share consistent specifications, not just the first sample checked.
H. Bulk B2B Procurement
Full datasheet review, sample approval before committing to volume, and supplier documentation (including GST invoicing) all become standard procurement steps rather than optional extras.
17. What B2B Buyers Should Ask a CCTV Cable Supplier
- Is the conductor pure copper or CCA — for both the video core and power cores?
- What is the actual conductor size / AWG?
- What is the video core construction (centre conductor, dielectric, shielding)?
- What is the power core size and configuration?
- What is the actual supplied length per roll/box, and what's the tolerance?
- Is the cable indoor or outdoor rated?
- Is the jacket UV resistant, and is there documentation to support that?
- What is the overall cable diameter?
- Is a technical datasheet available for review?
- Can you provide a sample before a bulk order is placed?
- What is the batch consistency across a full order?
- What is the packaging format (roll, box, reel)?
- What warranty or quality assurance policy applies?
- Is a GST invoice available for the order?
- What is the minimum order quantity (MOQ)?
- What is the typical lead time for the order size you need?
18. Common Mistakes When Buying 3+1 CCTV Cable in Bulk
Buying based only on price — the cheapest option in bulk is very often CCA with minimal jacket thickness, and the total cost of rework or replacement can outweigh the initial savings.
Assuming "copper" means 100% copper — some listings use "copper" loosely; always confirm pure copper vs CCA explicitly.
Not checking conductor size — relying on the supplier's general description instead of requesting the actual AWG or diameter figure.
Ignoring outdoor requirements — assuming standard indoor cable will hold up outdoors without verifying UV/weather rating.
Checking only outer diameter — using overall cable thickness as a proxy for quality, when it doesn't confirm conductor size.
Not testing a sample — committing to a bulk order without physically inspecting or testing a sample first.
Not confirming actual cable length — assuming a labelled length (e.g., "90m") is accurate without verification.
Ignoring packaging — overlooking how roll/box format affects handling, storage, and installation efficiency at scale.
Mixing different batches without verification — combining cable from different production runs without confirming consistent specifications.
Choosing cable without considering camera power requirements — selecting a power conductor size without checking it against actual camera draw and run distance.
19. 3+1 CCTV Cable Specification Checklist for Dealers
| Check | Why It Matters |
|---|---|
| Pure copper / CCA | Determines conductivity, power delivery, and long-term durability |
| Video core | Confirms centre conductor and shielding quality for signal transmission |
| Power core | Determines current-carrying capability for camera power |
| AWG | Confirms actual conductor thickness beyond outer cable diameter |
| Jacket | Determines mechanical protection and environmental suitability |
| UV/weather resistance | Confirms suitability for outdoor installation |
| Flame retardancy | Relevant for commercial/building code requirements |
| Length | Confirms accurate quantity per roll/box for cost planning |
| Diameter | Affects conduit sizing and logistics/storage planning |
| Packaging | Affects handling efficiency during installation |
| Sample approval | Verifies specifications match the datasheet before bulk commitment |
| Supplier documentation | Supports quality claims with actual evidence, not verbal assurance |
Frequently Asked Questions
What are the specifications of a 3+1 CCTV cable?
Key specifications include the video conductor construction, power conductor material and size, shielding, insulation, outer jacket type, and — where relevant — outdoor/UV rating and flame-retardant properties. Since 3+1 is a market term, exact figures vary by manufacturer and should be verified via datasheet.
What does 3+1 mean in CCTV cable?
It refers to a cable combining a coaxial video core with a separate power cable (typically 2 conductors) inside one jacket, allowing a single cable to carry both video and power to an analog camera.
What conductor is used in 3+1 CCTV cable?
Typically copper or CCA (copper-clad aluminium), used in both the coaxial centre conductor and the power cores. The exact material should be confirmed with the supplier rather than assumed.
Is pure copper better than CCA for 3+1 CCTV cable?
Pure copper generally offers better conductivity, lower resistance, and better durability than CCA, particularly for power delivery over longer runs. CCA is not unusable, but its trade-offs should be understood before bulk sourcing.
What AWG should a 3+1 CCTV cable have?
There's no single universal AWG requirement — the right conductor size depends on your camera's power draw and the cable run distance. Always confirm the specific AWG from the datasheet rather than assuming a standard figure.
Can 3+1 CCTV cable be used outdoors?
Yes, but only if it's specifically rated for outdoor/UV and weather exposure. Standard indoor-rated 3+1 cable is not automatically suitable for outdoor installation.
What is the difference between 3+1 and 4+1 CCTV cable?
3+1 typically means one video/coaxial core plus three power cores, while 4+1 means one video/coaxial core plus four power cores. The exact conductor size and construction can vary by manufacturer, so the product datasheet should be checked before procurement.
How long is a 3+1 CCTV cable roll?
Common market lengths include 50m, 90m, 100m, and 180m, though this varies by manufacturer and isn't a fixed universal standard. Always confirm the actual supplied length and tolerance.
Can 3+1 CCTV cable be used for IP cameras?
No, 3+1 cable is built for analog/HD-over-coax CCTV systems using BNC connectors. IP cameras connect via Ethernet, typically using CAT5e or CAT6 cable instead.
What should I check before buying 3+1 CCTV cable in bulk?
Verify conductor material and size, video core construction, jacket rating, cable length, outer diameter, batch consistency, and request supplier documentation and a sample before committing to volume.
How do I verify whether a CCTV cable is pure copper?
Request the datasheet with conductor material clearly specified, and where possible, have a sample physically tested or inspected — visual inspection alone often isn't sufficient to reliably distinguish pure copper from CCA.
What should a CCTV cable supplier provide to a B2B buyer?
A technical datasheet, sample approval before bulk order, clear conductor material and size specifications, batch consistency assurance, packaging details, warranty/quality policy, and GST invoicing for the order.
Conclusion
3+1 is a configuration term, not a fixed specification — the actual quality of a 3+1 CCTV cable depends on its conductor material, conductor size, shielding, insulation, and jacket construction, all of which can vary between manufacturers.
For B2B procurement, this means:
- Always request and review the actual datasheet rather than relying on a general product description
- Verify pure copper vs CCA explicitly, especially for bulk or long-run orders
- Test or inspect a sample before committing to volume
- Confirm outdoor rating and flame-retardant claims with documentation, not verbal assurance
- Match conductor size and material to your actual camera power requirements and run distances
A specification-led procurement process protects installers and dealers from inconsistent batches and underperforming cable — which ultimately costs more in rework than the cable itself.
Looking for 3+1 CCTV cable for dealer, installer, or bulk requirements? Explore JUAA's CCTV cable range or contact the team for product and bulk-order information.
Explore JUAA 3+1 CCTV Cable